Utah Administrative Code
Topic - Natural Resources
Title R652 - Forestry, Fire and State Lands
Rule R652-122 - Cooperative Agreements
Section R652-122-1500 - Minimum Standards for Wildland Firefighting Equipment
Current through Bulletin 2024-18, September 15, 2024
(1) The following standards are applicable to equipment used by fire departments representing those counties who have cooperative wildland fire protection agreements with the state. This includes county fire departments and other fire departments which are contracted with the counties to provide fire protection on private wildland. The Utah Division of Forestry, Fire and State Lands has determined that this standard be met by June 1, 2006.
(2) Engines and water tenders used on private wildland fires within the county's jurisdiction will meet the standard for the type of equipment plus appropriate hand tools and water handling equipment as determined by the National Wildfire Coordinating Group.
TABLE 1 Engines |
|||
Component |
Type 1 |
Type 2 |
Type 3 |
Pump Rating - gpm |
1,000+ @ 150 psi |
250+ @ 150 psi |
150+ @ 250 psi |
Tank Capacity - gal |
400+ |
400+ |
500+ |
Hose 2.5 inch |
1,200 ft |
1,000 ft |
-- |
Hose 1.5 inch |
400 ft |
500 ft |
500 ft |
Hose 1 inch |
-- |
-- |
500 ft |
Ladders |
48 ft |
48 ft |
-- |
Master Stream -- gpm |
500 |
-- |
-- |
Personnel - minimum |
4 |
3 |
2 |
Component |
Type 4 |
Type 5 |
Type 6 |
Pump Rating - gpm |
50 @ 100 psi |
50 @ 100 psi |
30 @ 100 psi |
Tank Capacity - gal |
750+ |
400 - 750 |
150 - 400 |
Hose 2.5 inch |
-- |
-- |
-- |
Hose 1.5 inch |
300 ft |
300 ft |
300 ft |
Hose 1 inch |
300 ft |
300 ft |
300 ft |
Ladders |
-- |
-- |
-- |
Master Stream -- gpm |
-- |
-- |
-- |
Personnel -minimum |
2 |
2 |
2 |
TABLE 2 Water Tenders |
|||
Component |
Type 1 |
Type 2 |
Type 3 |
Tank Capacity - gal |
5,000+ |
2,500+ |
1,000+ |
Pump Capacity - gpm |
300+ |
200+ |
200+ |
Off Load Capacity - gpm |
300+ |
200+ |
200+ |
Max Refill Time -- min |
30 |
20 |
15 |
Personnel tactical/nontactical |
2/1 |
2/1 |
2/1 |