A. Headroom clearance for inclined wheelchair lifts throughout the range of travel shall be not less than 80 inches (2032 mm) as measured vertically from the leading edge of the platform floor.

B. For existing facilities only, in the event that it is not technically or economically feasible to provide other means of access for disabled persons, inclined wheelchair lifts may be installed if all of the following conditions are met:

1. The appropriate building inspection jurisdiction approves the use of an inclined wheelchair lift for the specific application.

2. Headroom clearance throughout the range of travel shall be not less than 60 inches as measured vertically from the leading edge of the platform floor.

3. The passenger restriction sign as required by ASME A18.1 3.1.2.3 shall be amended as follows: "PHYSICALLY DISABLED PERSONS ONLY. NO FREIGHT. HEADROOM CLEARANCE IS LIMITED. USE ONLY IN THE SITTING POSITION".

Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.