Utah Administrative Code
Topic - Labor Commission
Title R616 - Boiler, Elevator and Coal Mine Safety
Rule R616-3 - Elevator Rules
Section R616-3-10 - Hydraulic Elevator Piping

Universal Citation: UT Admin Code R 616-3-10

Current through Bulletin 2024-06, March 15, 2024

A. This rule establishes minimum standards for hydraulic fluid piping in hydraulic elevators. The piping specifications referred to in this rule are governed by ASME or ASTM piping specifications (e.g. ASME Specification SA-53 Table X2.4).

B. Hydraulic elevators not incorporating a safety valve may use schedule 40 piping.

C. For newly installed hydraulic elevators that do incorporate a safety valve:

1. Where piping is protected by the safety valve, schedule 40 piping may be used;

2. Where grooved or threaded connections are used in piping that is unprotected by the safety valve, i.e. between the safety valve and the hydraulic jack(s), nominal pipe size (NPS)3 or schedule 80 piping may be used;

3. Where piping is unprotected by the safety valve, but welded or bolted flange connections are used, schedule 40 piping may be used.

Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.