Utah Administrative Code
Topic - Health
Title R392 - Population Health, Environmental Health
Rule R392-302 - Design, Construction and Operation of Public Pools
Section R392-302-19 - Circulation Systems
Current through Bulletin 2024-06, March 15, 2024
(1) The manager shall ensure that:
(2) A variable speed pump is permitted for pool water circulation if the manager ensures that the minimum circulation flow rate in the approved design and the minimum turnover rate required in Table 1 is maintained, and the requirements of Section R392-302-25 are met.
(3) The manager shall ensure that:
(4) The manager shall ensure that the circulation system includes a pump strainer that:
(5) The manager shall ensure that a pool facility has a vacuum-cleaning system that:
(6) The manager shall ensure that pool water boilers and pressure vessels:
(7) The manager shall ensure that pool water heat exchangers:
(8) The manager shall ensure that each air induction system is designed and maintained to prevent:
(9) Notwithstanding Subsection R392-302-4(1), the manager shall ensure that by January 31, 2023 each chemical feed system includes two layers of interlocking protection for a low or no flow condition so that the operation of any chemical feeder is dependent upon the operational flow of the main circulation system and:
(10) The local health officer may require the manager to demonstrate that the circulation system is performing in accordance with the approved design.
(11) The local health officer may reduce the head loss requirement for pool inlet orifices as described in Subsection (1)(l)(iii) if the manager can demonstrate that at least a six to one pressure ratio from the pool inlet orifice to the return loop is maintained.
TABLE 1 Circulation |
|||
Pool Type |
Minimum Number of Wall Inlets |
Minimum Number of Skimmers per 3,500 square feet of surface area or less |
Minimum Turnover Rate |
1. Swimming pool |
One per ten linear feet of perimeter or fraction thereof |
One per 500 square feet of surface area |
Six hours |
3. Wading pool |
One per 20 linear feet of perimeter, or fraction thereof, with a minimum of two equally spaced |
One per 500 square feet of surface area |
One hour |
4. Spa pool |
One per 20 linear feet or fraction thereof |
One per 100 square feet of surface area |
1/2 hour |
5. Wave pool |
One per ten linear feet or fraction thereof |
One per 500 square feet of surface area |
Six hours |
6. Splash pool |
One per ten linear feet or fraction thereof |
One per 500 square feet of surface area |
One hour |
7. Vehicle slide |
One per ten linear feet or fraction thereof |
One per 500 square feet of surface area |
One hour |
8. Special purpose pool |
One per ten linear feet or fraction thereof |
One per 500 square feet of surface area |
One hour |