Utah Administrative Code
Topic - Health
Title R392 - Population Health, Environmental Health
Rule R392-200 - Sanitation and Safety of Schools
Section R392-200-8 - Construction and Maintenance of Physical Facilities - General

Universal Citation: UT Admin Code R 392-200-8

Current through Bulletin 2023-24, December 15, 2023

The governing body shall ensure that:

(1) each school building floor, wall, and ceiling is constructed with materials that are durable and easily cleanable, and maintained in clean and good condition;

(2) each plumbing fixture is sized, installed, and maintained in accordance with the requirements of Plumbing Code, local health department regulations, and the ADA.

(3) roof and plumbing water leaks are repaired and the area cleaned and dried as quickly as possible to discourage mold growth;

(4)

(a) lighting in each part of a school building:
(i) is provided using permanently fixed artificial light sources; and

(ii) when measured 30 inches from the floor, has the capability to provide at least the minimum required illumination levels as listed in Table 1 during hours of use;

(b) light fixtures located in each of the following areas are shatter resistant or have a protective shield to contain broken glass if the bulb or tube is broken or shattered:
(i) shops;

(ii) life skills;

(iii) cafeterias;

(iv) kitchens;

(v) food preparation areas;

(vi) toilet rooms;

(vii) shower areas;

(viii) locker rooms; and

(ix) gymnasium;

(c) light fixtures are cleaned and repaired as needed; and

(d) burned out bulbs or lamps are replaced as often as needed to maintain the illumination levels required in this section.

TABLE 1

Minimum Required Illumination Levels

Area

Footcandle Level

General instruction, including classroom, study hall, music room, lecture room, handwritten work area, and library.

35.0

Special instruction -- CTE and high-risk areas

50.0

Gymnasium - auxiliary spaces, shower rooms, and locker rooms

10.0

Gymnasium - main recreation spaces

25.0

Auditorium, faculty and staff lunchroom, assembly and multi-purpose room, and similar room not routinely used for instruction

30.0

Corridor, commons, stairs, hallway, indoor passageway, storeroom, and similar areas

10.0

Toilet room

15.0

Office

35.0

Conference room

30.0

Media center

25.0

Building entrances, parking areas, roads, and similar areas

0.2

(5) when provided, each sleeping area is provided with a cot, mat, or floor pad and that:

(a) each reusable cover supplied by the school is easily cleanable and maintained in good repair;

(b) when in use, the cover is cleaned between each user and at least weekly, if reused by the same student; and

(c) each disposable cover is discarded after use;

(6) carpets, throw rugs, or furniture with a permeable fabric cover used for sitting shall be cleaned every at least other month of use, and as needed when soiled.

(7) items described in Subsections (5) and (6) that require laundering are not washed in laundry facilities that are designated for the school's food establishment.

Amended by Utah State Bulletin Number 2018-12, effective 5/31/2018

Adopted by Utah State Bulletin Number 2022-19, effective 9/27/2022

Amended by Utah State Bulletin Number 2023-13, effective 6/14/2023

Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.