Utah Administrative Code
Topic - Environmental Quality
Title R315 - Waste Management and Radiation Control, Waste Management
Rule R315-264 - Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities
Section R315-264-198 - Special Requirements for Ignitable or Reactive Wastes
Universal Citation: UT Admin Code R 315-264-198
Current through Bulletin 2024-06, March 15, 2024
(a) Ignitable or reactive waste shall not be placed in tank systems, unless:
(1) The waste
is treated, rendered, or mixed before or immediately after placement in the
tank system so that:
(i) The resulting waste,
mixture, or dissolved material no longer meets the definition of ignitable or
reactive waste under Sections
R315-261-21
or 23, and
(ii) Subsection
R315-264-17(b)
is complied with; or
(2) The waste is stored or treated in such a
way that it is protected from any material or conditions that may cause the
waste to ignite or react; or
(3)
The tank system is used solely for emergencies.
(b) The owner or operator of a facility where ignitable or reactive waste is stored or treated in a tank shall comply with the requirements for the maintenance of protective distances between the waste management area and any public ways, streets, alleys, or an adjoining property line that can be built upon as required in Tables 2-1 through 2-6 of the National Fire Protection Association's "Flammable and Combustible Liquids Code," (1977 or 1981), incorporated by reference, see Section R315-260-11.
Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.