Utah Administrative Code
Topic - Environmental Quality
Title R315 - Waste Management and Radiation Control, Waste Management
Rule R315-15 - Standards for the Management of Used Oil
Section R315-15-18 - Polychlorinated Biphenyls (PCBs)

Universal Citation: UT Admin Code R 315-15-18

Current through Bulletin 2024-06, March 15, 2024

(a) Used oil containing polychlorinated biphenyl (PCB) concentrations of 50 ppm and above is subject to TSCA regulations in 40 CFR 761. Used oil containing PCB concentrations greater than or equal to 2 ppm but less than 50 ppm is subject to both R315-15 and 40 CFR 761.

(b) Used oil transporter PCB testing. Used oil transporters shall determine the PCB content of used oil being transported is less than 50 ppm prior to transferring the oil into the transporter's vehicles. The transporter shall make this determination as follows:

(1) Used dielectric oil. Dielectric oil used in transformers and other high voltage devices shall be certified to be less than 50 ppm prior to loading to the transporter's vehicle through laboratory testing following the procedures described in R315-15-18(d).

(2) Other used oils shall be certified to be less than 50 ppm prior to transfer through either:
(A) Laboratory testing following the procedures described in R315-15-18(d) below, or

(B) Written certification from the generator that the PCB content of the used oil is less than 50 ppm based on manufacturing specifications and process knowledge.

(c) Used oil marketer PCB testing. To ensure that used oil destined to be burned for energy recovery is not a regulated waste under the TSCA regulations, used oil fuel marketers shall determine whether the PCB content of used oil being burned for energy recovery is below 2 ppm. A marketer shall make this determination in a manner consistent with the used oil marketer's sampling and analysis plan.

(d) Laboratory testing for PCBs. Used oil testing for total PCBs shall include the following Aroclors: 1016, 1221, 1232, 1242, 1248, 1254, and 1260. If plasticizers (used in polyvinyl chloride plastic, neoprene, chlorinated rubbers, laminating adhesives, sealants and caulk and joint compounds etc.) are present, then the used oil shall also be analyzed for Aroclors 1262 and 1268. If other Aroclors are known or suspected to be present, then the used oil shall be analyzed for those additional Aroclors.

(e) The following Utah Certified Laboratory SW-846 methodologies shall be used for PCBs:

(1) Preparation method 3580A, clean up method 3665A, and analytical method 8082A.

(2) Individual Aroclors shall be reported with a reporting limit of 1 ppm or less.

(3) If the source of the PCBs is known to be an Aroclor, and the Aroclor is unlikely to be significantly altered in homologue composition such as weathering, Aroclors listed in R315-15-18(d) shall be reported. Analytical results from all 209 individual congeners or ten homologue groups shall be submitted for any sample that has an altered homologue composition such as weathering unless prior approval is obtained from the Director.

Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.