Utah Administrative Code
Topic - Environmental Quality
Title R307 - Air Quality
Rule R307-352 - Metal Container, Closure, and Coil Coatings
Section R307-352-4 - VOC Content Limits
Current through Bulletin 2024-06, March 15, 2024
(1) Operations that use aerosol coating products are exempt.
(2) No owner or operator shall apply coatings with a VOC content greater than the amounts specified in Table 1, unless the owner or operator uses an add-on control device as specified in R307-352-6.
TABLE 1
METAL CONTAINER AND CLOSURE COIL COATING LIMITATIONS (values in pounds VOC per gallon of coating, minus water and exempt solvents (compounds not classified as VOC as defined in R307-101-2 ), as applied)
Coating Category VOC |
Content Limits (lb/gal) |
CANS |
|
Sheet basecoat (interior and exterior) and overvarnish |
1.9 |
Two-piece can exterior basecoat, overvarnish, and end coating |
2.1 |
Interior body spray |
|
Two-piece cans |
3.5 |
Three-piece cans |
3.0 |
Three-piece can side seam spray |
5.5 |
End sealing compound: Food cans, non-food cans, and beverage cans |
0.1 |
Exterior body spray |
3.5 |
PAILS AND LIDS |
|
Body spray |
|
Reconditioned interior |
4.2 |
Reconditioned exterior |
3.5 |
New interior |
3.5 |
New exterior |
2.8 |
End sealing compound |
0.5 |
Inks, all applications |
2.5 |
Coil Coil coating |
1.7 |