Utah Administrative Code
Topic - Environmental Quality
Title R307 - Air Quality
Rule R307-348 - Magnet Wire Coatings
Section R307-348-6 - Add-On Control Systems Operations
Universal Citation: UT Admin Code R 307-348-6
Current through Bulletin 2024-06, March 15, 2024
(1) If an add-on control system is used it must be installed, operated, and maintained in accordance with manufacturer recommendations.
(a) An add-on control device
must have a 90% or greater capture and control efficiency rating. Efficiency
must be determined using EPA approved methods as follows:
(i) Capture efficiency must be determined
according to EPA's "Guidelines for Determining Capture Efficiency," January 9,
1995 and 40 C.F.R. Parts 51, Appendix M, Methods 204-204F, as
applicable.
(ii) Control efficiency
must be determined using test methods in Appendices A-1, A-6, and A-7 to 40
C.F.R. Part 60, for measuring flow rates, total gaseous organic concentrations,
or emissions of exempt compounds, as applicable.
(iii) An alternative test method may be
substituted for the preceding test methods after review and approval by the EPA
Administrator.
Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.