Utah Administrative Code
Topic - Environmental Quality
Title R307 - Air Quality
Rule R307-344 - Paper, Film, and Foil Coatings
Section R307-344-5 - Work Practices
Universal Citation: UT Admin Code R 307-344-5
Current through Bulletin 2024-06, March 15, 2024
(1) Control techniques and work practices are to be implemented at all times to reduce VOC emissions. Control techniques and work practices include:
(a) Using covered containers for solvent
wiping cloths;
(b) Using collection
hoods for areas where solvent is used for cleanup;
(c) Minimizing spills of VOC-containing
cleaning materials;
(d) Conveying
VOC-containing materials from one location to another in closed containers or
pipes; and
(e) Cleaning spray guns
in enclosed systems
(2) No person shall apply coatings unless these materials are applied with equipment operated according to the manufacturer's specifications, and by the use of one of the following methods:
(a) Flow
coater;
(b) Roll coater;
(c) Dip coater;
(d) Foam coater;
(e) Die coater;
(f) Hand application methods;
(g) High-volume, low pressure (HVLP) spray;
or
(h) Other application method
capable of achieving 65% or greater transfer efficiency, as certified by the
manufacturer.
(3) Solvent cleaning operations shall be performed using cleaning materials having a VOC composite vapor pressure no greater than 1 mm Hg at 20 degrees Celsius, unless an add-on control device is used as specified in R307-344-6.
Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.