Utah Administrative Code
Topic - Environmental Quality
Title R307 - Air Quality
Rule R307-230 - NO[x] Emission Limits for Natural Gas-Fired Water Heaters
Section R307-230-5 - Standards

Universal Citation: UT Admin Code R 307-230-5

Current through Bulletin 2024-06, March 15, 2024

(1) No person shall sell or install any natural gas-fired water heater with an emission rate exceeding the limits described in R307-230-5(1)(a).

(a) Subsections R307-230-5(1)(i) -(v) provide the NO x emission limits for natural gas-fired water heaters.
(i) Water heaters up to 75,000 BTU/hr, excluding those in mobile homes: 10 ng/Joule of heat output or 15 ppm at 3% O 2.

(ii) Water heaters 75,001-2,000,000 BTU/hr: 14 ng/Joule of heat output or 20 pmm at 3% O2.

(iii) Mobile home water heaters: 40 ng/Joule of heat output or 55 ppm at 3% O2.

(iv) Pool/spa heaters less than or equal to 400,000 BTU/hr: 40 ng/Joule of heat output or 55 ppm at 3% O2.

(v) Pool/spa heaters 400,001-2,000,000 BTU/hr: 14 ng/Joule of heat output or 20 pmm at 3% O2.

(2) The water heater manufacturer shall display the model number on each unit and the appropriate NOx emission rating on a permanent label on each unit.

(3) Manufacturers shall use SCAQMD Method 100-1 to comply with the NOx standards in R307-230-5(1)(a).

Disclaimer: These regulations may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.