Section 331.106 - Remedial Action for Excursion
Current through Reg. 50, No. 13; March 28, 2025
If the verifying analysis indicates the existence of an excursion in a designated monitor well, the operator shall take the following actions:
(1) notification--notify the commission regional office by the next working day by telephone and notify the executive director by letter postmarked within 48 hours of identification of the excursion. The notification must identify the affected monitor well and the control parameter concentrations.
(2) analysis--complete a groundwater analysis report for each affected well on forms provided by the executive director (including accuracy checks and stiff diagram) for the following: pH, calcium, magnesium, sodium, potassium, carbonate, bicarbonate, sulfate, chloride, silica, total dissolved solids (180 degrees Celsius), specific conductance and dilute conductance, uranium, radium-226 and any other specified constituents. Results shall be reported in accordance with § 331.85(f) of this title (relating to Reporting Requirements).