Texas Administrative Code
Title 30 - ENVIRONMENTAL QUALITY
Part 1 - TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
Chapter 115 - CONTROL OF AIR POLLUTION FROM VOLATILE ORGANIC COMPOUNDS
Subchapter H - HIGHLY-REACTIVE VOLATILE ORGANIC COMPOUNDS
Division 3 - FUGITIVE EMISSIONS
Section 115.787 - Exemptions
Current through Reg. 50, No. 13; March 28, 2025
(a) Components that contact a process fluid containing less than 5.0% highly-reactive volatile organic compounds by weight on an annual average basis are exempt from the requirements of this division (relating to Fugitive Emissions), except for § 115.786(e) and (g) of this title (relating to Recordkeeping Requirements).
(b) The following are exempt from the shaft sealing system requirements of § 115.783(3) of this title (relating to Equipment Standards):
(c) The following components are exempt from the requirements of this division:
(d) All pumps, compressors, and agitators that are equipped with a shaft sealing system that prevents or detects emissions of VOC from the seal are exempt from the monitoring requirement of § 115.781(b) and (c) of this title (relating to General Monitoring and Inspection Requirements). These seal systems may include, but are not limited to, dual seals with barrier fluid at higher pressure than process pressure, seals degassing to vent control systems kept in good working order, or seals equipped with an automatic seal failure detection and alarm system. Submerged pumps or sealless pumps (including, but not limited to, diaphragm, canned, or magnetic driven pumps) may be used to satisfy the requirements of this subsection.
(e) Each pressure relief valve equipped with an upstream rupture disk is exempt from the requirements of § 115.781(b)(8) of this title, provided that the pressure relief valve complies with § 115.725(c) of this title (relating to Monitoring and Testing Requirements). The rupture disk must be replaced as soon as practicable, but no later than 30 calendar days after a failure is detected.
(f) The following valves are exempt from the requirements of § 115.783(5) of this title:
(g) Any site as defined in § 122.10 of this title with less than 100 valves in highly-reactive volatile organic compound service is exempt from § 115.788 of this title (relating to Audit Provisions).