Section 115.235 - Approved Test Methods
Universal Citation: 30 TX Admin Code § 115.235
Current through Reg. 50, No. 13; March 28, 2025
(a) In the Beaumont/Port Arthur, Dallas/Fort Worth, El Paso, and Houston/Galveston areas, the following testing requirements apply.
(1) The owner or operator of any tank-truck which is filled with or emptied of gasoline at any facility subject to §
115.214(a)(1)(C) or §
115.224(2) of this title (relating to Inspection Requirements), or which is filled with non-gasoline volatile organic compounds (VOC) at any facility subject to §
115.214(a)(1)(C) of this title shall cause each such tank to be tested annually to ensure that the tank is vapor-tight.
(2) Any tank failing to meet the testing criteria of paragraph (1) of this subsection shall be repaired and retested within 15 days.
(3) Testing required in paragraph (1) of this subsection shall be conducted in accordance with the following test methods, as appropriate:
(A) Test Method 27 (40 Code of Federal Regulations (CFR) 60, Appendix A) for determining vapor-tightness of gasoline delivery tank using pressure-vacuum test such that the pressure in the tank must change no more than three inches of water (0.75 kPa) in five minutes when pressurized to a gauge pressure of 18 inches of water (4.5 kPa) and when evacuated to a vacuum of six inches of water (1.5 kPa); or
(B) minor modifications to these test methods approved by the executive director.
(4) For tank-truck tanks which are filled with non-gasoline VOC at a facility subject to §
115.214(a)(1)(C) of this title, annual testing using the leakage test method described in 49 CFR 180.407(h) for specification cargo tanks is an acceptable alternative to Test Method 27 ( 40 CFR 60, Appendix A).
(b) In the covered attainment counties, the following testing requirements shall apply.
(1) The owner or operator of any tank-truck which is filled or emptied at any facility subject to §
115.214(b)(1)(C) or §
115.224(2) of this title shall cause each such tank to be tested annually to ensure that the tank is vapor-tight.
(2) Any tank failing to meet the testing criteria of paragraph (1) of this subsection shall be repaired and retested within 15 days.
(3) Testing required in paragraph (1) of this subsection shall be conducted in accordance with the following test methods, as appropriate:
(A) Test Method 27 (40 CFR 60, Appendix A) for determining vapor tightness of gasoline delivery tank using pressure-vacuum test such that the pressure in the tank must change no more than three inches of water (0.75 kPa) in five minutes when pressurized to a gauge pressure of 18 inches of water (4.5 kPa) and when evacuated to a vacuum of six inches of water (1.5 kPa); or
(B) minor modifications to these test methods approved by the executive director.
Disclaimer: These regulations may not be the most recent version. Texas may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.