Texas Administrative Code
Title 30 - ENVIRONMENTAL QUALITY
Part 1 - TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
Chapter 115 - CONTROL OF AIR POLLUTION FROM VOLATILE ORGANIC COMPOUNDS
Subchapter C - VOLATILE ORGANIC COMPOUND TRANSFER OPERATIONS
Division 1 - LOADING AND UNLOADING OF VOLATILE ORGANIC COMPOUNDS
Section 115.211 - Emission Specifications

Universal Citation: 30 TX Admin Code § 115.211

Current through Reg. 50, No. 13; March 28, 2025

The owner or operator of each gasoline terminal in the covered attainment counties and in the Beaumont/Port Arthur, Dallas/Fort Worth, El Paso, and Houston/Galveston areas, as defined in § 115.10 of this title (relating to Definitions), shall ensure that volatile organic compound (VOC) emissions from the vapor control system vent at gasoline terminals do not exceed the following rates:

(1) in the Beaumont/Port Arthur, Dallas/Fort Worth, El Paso, and Houston/Galveston areas, 0.09 pound per 1,000 gallons (10.8 mg/liter) of gasoline loaded into transport vessels.

(2) in the covered attainment counties, 0.17 pound per 1,000 gallons (20 mg/liter) of gasoline loaded into transport vessels.

Disclaimer: These regulations may not be the most recent version. Texas may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.