Texas Administrative Code
Title 30 - ENVIRONMENTAL QUALITY
Part 1 - TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
Chapter 113 - STANDARDS OF PERFORMANCE FOR HAZARDOUS AIR POLLUTANTS AND FOR DESIGNATED FACILITIES AND POLLUTANTS
Subchapter D - DESIGNATED FACILITIES AND POLLUTANTS
Division 3 - EMISSION GUIDELINES AND COMPLIANCE TIMES FOR SMALL MUNICIPAL WASTE COMBUSTION UNITS CONSTRUCTED ON OR BEFORE AUGUST 30, 1999
Section 113.2135 - How do I convert my 1-hour arithmetic averages into appropriate averaging times and units?
Current through Reg. 50, No. 13; March 28, 2025
(a) Use the equation in § 113.2171(a) of this title (relating to What equations must I use?) to calculate emissions at 7 percent oxygen.
(b) Use United States Environmental Protection Agency (EPA) Reference Method 19 in 40 Code of Federal Regulations (CFR) Part 60, Appendix A, §4.3, to calculate the daily geometric average concentrations of sulfur dioxide emissions. If you are monitoring the percent reduction of sulfur dioxide, use EPA Reference Method 19 in 40 CFR Part 60, Appendix A, §5.4, to determine the daily geometric average percent reduction of potential sulfur dioxide emissions.
(c) If you operate a Class I municipal waste combustion unit, use EPA Reference Method 19 in 40 CFR Part 60, Appendix A, §4.1, to calculate the daily arithmetic average for concentrations of nitrogen oxides.
(d) Use EPA Reference Method 19 in 40 CFR Part 60, Appendix A, §4.1, to calculate the 4-hour or 24-hour daily block averages (as applicable) for concentrations of carbon monoxide.