Texas Administrative Code
Title 25 - HEALTH SERVICES
Part 1 - DEPARTMENT OF STATE HEALTH SERVICES
Chapter 265 - GENERAL SANITATION
Subchapter M - INTERACTIVE WATER FEATURES AND FOUNTAINS
Section 265.305 - Circulation and Disinfectant Systems for Public Interactive Water Features and Fountains
Current through Reg. 49, No. 38; September 20, 2024
(a) General circulation requirements. The circulation system consisting of pumps, piping, filters, return inlets, water conditioning equipment, disinfection equipment, surge chamber, treatment tank and other ancillary equipment shall provide adequate circulation of water and be designed to accommodate 100% of the turnover flow rate and maintain the distribution of disinfectant through all parts of the public interactive water feature or fountain (PIWF).
(b) Circulation equipment. Where circulation equipment falls within the scope of NSF and ANSI Standard 50 (NSF/ANSI-50 Standard), such equipment shall meet the standard. Conformity with NSF/ANSI-50 as evidenced by the listing or labeling of such equipment by a testing laboratory or by separate documentation is required.
(c) Turnover rate. The turnover rate for the circulation of water in a PIWF that is combined or circulated with water from a pool shall be the same as the pool. The turnover rate for circulation of water in a stand-alone PIWF shall meet the following requirements.
(d) Treatment tank. The treatment tank shall: