Texas Administrative Code
Title 10 - COMMUNITY DEVELOPMENT
Part 1 - TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS
Chapter 80 - MANUFACTURED HOUSING
Subchapter B - INSTALLATION STANDARDS AND DEVICE APPROVALS
Section 80.22 - Generic Standards for Moisture and Ground Vapor Controls
Current through Reg. 49, No. 38; September 20, 2024
(a) If the used manufactured home is installed according to the state's generic standards and the space under the home is to be enclosed with skirting and/or other materials provided by the retailer and/or installer, the enclosure must meet the following requirements:
(b) The generic ground vapor control measure shall consist of a ground vapor retarder that is minimum 6 mil polyethylene sheeting or its equivalent, installed so that the area under the home is covered with sheeting and overlapped approximately 12 inches at all joints. Any tear larger than 18 inches long or wide must be taped using a material appropriate for the sheeting used. The laps should be weighted down to prevent movement. Any small tears and/or voids around construction (footings, anchor heads, etc.) are acceptable.