(1) Unless
otherwise provided by applicable law or the provisions of this chapter, the
required minimum codes and standards for the construction of one (1) and two
(2) family dwellings, townhouses, and additions thereto of thirty (30) square
feet or more of interior space in the State of Tennessee shall be those
prescribed in the following publications:
(a)
International Residential Code (IRC), 2018 edition, published by the
International Code Council, Inc. (ICC), 500 New Jersey Avenue Northwest, 6th
Floor, Washington, D.C., 20001, and Appendix Q except that:
1. Section R313 Automatic Fire Sprinkler
Systems is not mandatory, pursuant to T.C.A. §
68-120-101(a)(8).
2. Chapters 34-43 relating to Electrical
Installations are deleted and electrical standards adopted in 0780-02-01
Electrical Installations shall apply.
3. Figure R301.2(2) Seismic Design Categories
is deleted and replaced with Figure R301.2(2) Seismic Design Categories Site
Class D from 2015 IRC.
4. Section
R314.6 Power Source relating to Smoke Alarms is amended to create Exception 3
that shall read:
Exception 3. Interconnection and hardwiring of smoke alarms
in existing areas shall not be required where the alterations or repairs do not
result in the removal of interior walls or ceiling finishes exposing the
structure.
5. Section
N1102.4.1.2 (R402.4.1.2) Testing is replaced with Section N1102.4.2.1 Testing
Option and Section N1102.4.2.2 Visual Inspection from 2009 IRC.
6. Section N1103.3.3 (R403.3.3) Duct Testing
(Mandatory) and Section N1103.3.4 (R403.3.4) Duct Leakage (Prescriptive) are
optional.
7. Table N1102.1.2
(R402.1.2) Insulation and Fenestration Requirement by Component and Table
N1102.1.4 (R402.1.4) Equivalent U-Factors from 2018 IRC are replaced with Table
N1102.1 Insulation and Fenestration Requirements by Component and Table
N1102.1.2 Equivalent U-Factor from 2009 IRC.
8. Section N1102.4.4 (R402.4.4) Rooms
Containing Fuel-Burning Appliances is deleted in its entirety.
9. Table N1102.1 Insulation and Fenestration
Requirements by Component in the 2009 edition is adopted and amended by adding
the following as footnote "l": "Log walls complying with ICC400 and with a
minimum average wall thickness of 5" or greater shall be permitted in Zone 3
when a Fenestration U-Factor of .50 or lower is used, a Skylight U-Factor of
.65 or lower is used, a Glazed Fenestration SHGC of .30 or lower is used, a 90
AFUE Furnace is used, an 85 AFUE Boiler is used, and a 9.0 HSPF Heat Pump
(heating) and 15 SEER (cooling) are used."
10. Table N1102.1 Insulation and Fenestration
Requirements by Component in the 2009 edition is adopted and amended by adding
the following as footnote "m": "Log walls complying with ICC400 and with a
minimum average wall thickness of 5" or greater shall be permitted in Zone 4
when a Fenestration U-Factor of .35 or lower is used, a Skylight U-Factor of
.60 or lower is used, a 90 AFUE Furnace is used, an 85 AFUE Boiler is used, and
a 9.0 HSPF Heat Pump (heating) and 15 SEER (cooling) are used."
(b) International Energy
Conservation Code (IECC), 2018 edition, published by the ICC, except that:
1. Section R402.4.1.2 Testing is deleted and
replaced with Section 402.4.2.1 Testing Option and Section 402.4.2.2 Visual
Inspection Option from 2009 IECC.
2. Section R403.3.3 Duct Testing (Mandatory)
and Section R403.3.4 Duct Leakage (Prescriptive) are optional.
3. Table 402.1.2 Insulation and Fenestration
Requirements by Component and Table R402.1.4 Equivalent U-Factors are deleted
and replaced with Table 402.1.1 Insulation and Fenestration Requirements by
Component and Table 402.1.3 Equivalent U-Factors 2009 IECC.