Rules & Regulations of the State of Tennessee
Title 0780 - Commerce and Insurance
Subtitle 0780-02 - Division of Fire Prevention
Chapter 0780-02-08 - Used Factory-Manufactured Homes
Section 0780-02-08-.02 - STANDARDS
Universal Citation: TN Comp Rules and Regs 0780-02-08-.02
Current through September 24, 2024
(1) A ''Class A used manufactured home'' must comply with the following safety standards:
(a) Smoke Detectors.
1. General. At least one (1) smoke detector,
investigated and listed in accordance with Tenn. Code Ann.
§68-102-148, shall be installed to protect each separate
bedroom area.
2. Location. A smoke
detector shall be installed in the hallway or space communicating with each
bedroom area between the living area and the first bedroom area. When located
in a hallway, the detector shall be between the return air intake and the
living area. Used manufactured homes having bedroom areas separated by
common-use areas, such as kitchen, dining room, living room, or family room
(but not a bathroom or utility room), shall have at least one (1) detector
protecting each bedroom area.
3.
Installation. Each smoke detector shall be installed in accordance with its
listing.
4. Testing. The smoke
detector shall be tested for operation at the time of sale or set up. The
retailer shall provide testing and maintenance instructions for the use, unless
the smoke detector was installed before the retailer obtained the used
manufactured home.
(b)
Electrical.
1. Distribution Panels.
Distribution panels shall be installed in compliance with the approved listing,
complete with required breakers or fuses, with all unused openings covered with
blank covers approved and listed for the purpose. Connections shall be checked
for tightness. Panels shall be readily accessible.
2. Electrical System. The electrical system
(switches, receptacles, fixtures, etc.) shall be properly installed, wired, and
supported, and shall be in a safe, usable condition. Aluminum conductors shall
be checked to assure tight connections. Grounds shall be checked for tightness
and location.
3. Testing. The used
manufactured home shall be subjected to:
(i)
An electrical continuity test to assure that all metallic parts are properly
bonded;
(ii) An electrical
operational test to demonstrate that all fixtures and equipment, except water
heater, ranges, air conditioners, and electric furnaces, are connected and in
working order; and
(iii) An
electrical polarity check to determine that connections have been properly
made.
(c)
Plumbing.
1. Fixtures.
(i) All plumbing fixtures shall be protected
with approved workable "P" traps.
(ii) All plumbing fixtures shall be in
workable condition and properly vented through the roof.
(iii) An anti-siphon trap vent device or
mechanical vent may be used to vent single fixtures except commodes.
2. Water Supply. Water piping
shall not be bent or kinked so as to retard or obstruct the flow of the water
supply.
3. Water Heater Safety
Device. The water heater shall be equipped with an approved listed relief valve
to provide temperature and pressure relief.
(d) Heat-Producing Equipment.
1. Heating System.
(i) Equipment. Heating equipment (furnace,
wall heaters, thermostats, etc.) shall be in safe and operable conditions. All
ducts shall be in usable conditions (not collapsed), with all joints, furnace
connections, etc., mechanically secure and sealed (exterior and
interior).
(ii) Vents. All gas
water heater and furnace venting systems shall be in safe and operable
conditions. No vents will terminate within roof, wall, or floor
cavity.
(e)
General.
1. Exhaust vents in bathrooms and at
the range shall be operable.
2.
Exterior doors (including sliding glass) shall be operable.
3. Insulation missing from exposed areas
shall be replaced. All holes in the bottom board shall be securely
sealed.
Authority: T.C.A. §§ 68-126-202, 68-126-210, and 68-126-405.
Disclaimer: These regulations may not be the most recent version. Tennessee may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.