Rules & Regulations of the State of Tennessee
Title 0400 - Environment and Conservation
Subtitle 0400-52 - Drilling, Re-Entering, Plugging and Abandoning Exploratory and Exploitation Oil and Gas Wells (Transferred from 1040-02)
Chapter 0400-52-07 - Casing Program (Transferred from 1040-02-07)
Section 0400-52-07-.01 - CASING REQUIREMENTS
Current through September 24, 2024
(1) Surface Casing
(2) If intermediate casing is used, the operator shall set an intermediate string of casing prior to drilling into any known oil and gas producing zone. Casing shall have a minimum internal pressure rating of 110% of maximum formation pressure reasonably expected based on the depth and location of the well. The operator shall cement the intermediate casing at a minimum of 100 feet into the surface casing. Casing string shall be deep enough to prevent underground blowout from anticipated bottomhole pressures. Casing shall have an external collapse pressure rating to handle cement design from casing shoe to surface. The operator shall use cement with 500 psi compressive strength and have a minimum 8 hour wait, or until cement has adequately set, prior to drilling the shoe out. .
(3) The operator shall present all cement and casing designs on a specifications sheet with permit application for approval. A copy of cement tickets shall be kept on location to be viewed by the inspector until the drill rig is removed. In unknown or over pressured conditions a 5000 psi rating on casing shall apply. The operator shall attach a copy of all cement tickets to the well history tickets and shall include all volumes and pressures of job from start to finish. To ensure adequate annular space for cementing, the annular space outside the casing shall be at least as large as follows for the applicable casing size:
Up to 7" Outside Diameter (O.D.) Casing O.D. + 1 1/2"
More than 7" and less than 10 3/4" O.D. Casing O.D. + 2"
More than 10 3/4 "O.D. Casing O.D + 3"
(4) Any wells on the Cumberland Plateau drilled to depths above the Chattanooga Shale may be eligible for variances on the casing requirements in this rule by making a specific request to the Supervisor.
Authority: T.C.A §§ 60-1-201 et seq., and 4-5-201 et seq.