Rules & Regulations of the State of Tennessee
Title 0400 - Environment and Conservation
Subtitle 0400-48 - Water Resources (Groundwater Protection)
Chapter 0400-48-01 - Regulations To Govern Subsurface Sewage Disposal Systems (Transferred from 1200-01-06)
Section 0400-48-01-.11 - LOCATION OF SEPTIC TANKS, DOSING CHAMBERS AND ABSORPTION FIELDS

Current through September 24, 2024

(1) The location of septic tank, dosing chamber, advanced treatment system and disposal field shall be selected in accordance with the following minimum distances in feet, bearing in mind that local conditions may require increased distances of separation.

Septic and Dosing Tanks and / or

ATS

Disposal

Field

Water Supply

50

50

Dwellings

5

10

Property Lines

10

10

Easements Boundaries

10

10

*Gullies, Ravines, Dry Stream Beds, Natural Drainageways, Sinkholes, Streams and Cut Banks

15

25

Water Lines

10

10

House to Tank Connections

-

10

Septic and Dosing Tanks

-

5

*These distances may increase or decrease as soil conditions so warrant as determined by the Commissioner after a special investigation by an approved soil consultant.

Authority: T.C.A. §§ 68-221-401 et seq. and 4-5-201 et seq.

Disclaimer: These regulations may not be the most recent version. Tennessee may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.