The maximum allowable working pressure (MAWP) of a boiler is determined by the strength of the weakest part of the boiler. A boiler may not be operated above its MAWP.
The MAWP on the shell or drum is determined by the following formula:
MAWP = TS x t x E
Where
TS = 55,000 (lbs/sq in)
t = minimum thickness of the plate (in inches)
E = efficiency of the joint (nondimensional), as set forth in Appendix A at the end of this chapter
R = inside radius of the shell (in inches)
FS = safety factor of 5.0 (nondimensional)
General Authority: SDCL 34-29A-14.1.
Law Implemented: SDCL 34-29A-14.1.
Disclaimer: These regulations may not be the most recent version. South Dakota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.