South Dakota Administrative Rules
Title 61 - Department of Public Safety
Article 61:08 - Boilers
Chapter 61:08:09 - Historic power boilers
- Section 61:08:09:01 - Definitions
- Section 61:08:09:02 - Schedule of inspections
- Section 61:08:09:03 - Inspection fees
- Section 61:08:09:04 - Appeal from decision by inspector
- Section 61:08:09:05 - Internal inspection of boilers
- Section 61:08:09:06 - Preparation of boiler for internal inspection
- Section 61:08:09:07 - Internal inspection - Openings
- Section 61:08:09:08 - Internal inspection - Evidence of overheating
- Section 61:08:09:09 - Internal inspection - Condition of flues
- Section 61:08:09:10 - Internal inspection - Checking for cracks
- Section 61:08:09:11 - Internal inspection - Extent of corrosion
- Section 61:08:09:12 - Internal inspection - Test of staybolts
- Section 61:08:09:13 - Maximum allowable working pressure
- Section 61:08:09:14 - Requirements for hydrostatic pretest
- Section 61:08:09:15 - Hydrostatic pretest - Pipe requirements
- Section 61:08:09:16 - Hydrostatic pretest - Steam gauge connections
- Section 61:08:09:17 - Hydrostatic pretest - Steam gauge capacity
- Section 61:08:09:18 - Hydrostatic pretest - Safety valve requirements
- Section 61:08:09:19 - Hydrostatic pretest - Steam outlet requirements
- Section 61:08:09:20 - Hydrostatic pretest - Blowoff valve requirements
- Section 61:08:09:21 - Hydrostatic pretest - Feed water pipe requirements
- Section 61:08:09:22 - Hydrostatic pretest - Feed water supply
- Section 61:08:09:23 - Hydrostatic pretest - Water level indicator
- Section 61:08:09:24 - Requirements to perform hydrostatic test
- Section 61:08:09:25 - Required hydrostatic test pressure
- Section 61:08:09:26 - Hydrostatic test - Required water temperature
- Section 61:08:09:27 - Hydrostatic test - Safety valve and steam gauge requirements
- Section 61:08:09:28 - Duration of hydrostatic test
- Section 61:08:09:29 - Ultrasonic examination for thickness determination
- Section 61:08:09:30 - Internal inspection report
- Section 61:08:09:31 - External inspections and tests
- Section 61:08:09:32 - Preparation of boiler for external inspection
- Section 61:08:09:33 - External inspection - Cleanliness and ASME compliance
- Section 61:08:09:34 - External inspection - Evidence of leakage
- Section 61:08:09:35 - External inspection - Water glass requirements
- Section 61:08:09:36 - External inspection - Safety valve requirements
- Section 61:08:09:37 - External inspection - Blowoff piping requirements
- Section 61:08:09:38 - External inspection report
- Section 61:08:09:39 - Repairs to historic power boilers
- Section 61:08:09:40 - Minor repairs
- Section 61:08:09:41 - Major repairs
- Section 61:08:09:42 - Tests following major repairs
- Section 61:08:09:43 - Repair methods
- Section 61:08:09:44 - Repair of defects
- Section 61:08:09:45 - Repair of cracks
- Section 61:08:09:46 - Repair of minor cracks and imperfections
- Section 61:08:09:47 - Repair of cracks radiating from holes
- Section 61:08:09:48 - Repair of welded butt joints
- Section 61:08:09:49 - Repair of wasted surfaces
- Section 61:08:09:50 - Welding on butt straps
- Section 61:08:09:51 - Staybolt replacement
- Section 61:08:09:52 - Inspection of welds
- Section 61:08:09:53 - Approval of major repairs and report
- Section 61:08:09:54 - Requirements for construction of new boilers
- Section 61:08:09:55 - Qualifications of inspectors
- Appendix A - Guide to Riveted Joint Efficiencies
Disclaimer: These regulations may not be the most recent version. South Dakota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.