South Dakota Administrative Rules
Title 61 - Department of Public Safety
Article 61:08 - Boilers
Chapter 61:08:05 - Safety requirements
- Section 61:08:05:01 - General safety requirements
- Section 61:08:05:02 - Operating and limit controls required
- Section 61:08:05:03 - Positive flame failure cutoff required
- Section 61:08:05:04 - Pressure gauge required
- Section 61:08:05:05 - Accurate temperature gauge required for water heater boilers
- Section 61:08:05:06 - Gauge glass required on steam boilers
- Section 61:08:05:07 - Low-water fuel cutoffs required
- Section 61:08:05:08 - Blowdown valves required
- Section 61:08:05:09 - Feed water valve and piping requirements
- Section 61:08:05:10 - Mounting requirements for steam pressure gauges
- Section 61:08:05:11 - Sizing of thermal expansion tanks
- Section 61:08:05:12 - Water meter required.Repealed
- Section 61:08:05:13 - Shutoff switch required
- Section 61:08:05:14 - Age limit of nonstandard boilers
- Section 61:08:05:15 - Age limit of boilers in excess of 30 inches with lap-riveted longitudinal joints
- Section 61:08:05:16 - Computation of maximum allowable working pressure - Standard boilers
- Section 61:08:05:17 - Computation of maximum allowable working pressure - Nonstandard boilers
- Section 61:08:05:17.01 - Tensile strength
- Section 61:08:05:17.02 - Crushing strength of mild steel
- Section 61:08:05:17.03 - Strength of rivets in shear
- Section 61:08:05:17.04 - Factors of safety
- Section 61:08:05:18 - Maximum allowable working pressure for new cast iron boilers.Repealed
- Section 61:08:05:19 - Minimum safety factor for reinstalled boilers
- Section 61:08:05:20 - Safety valves required
- Section 61:08:05:21 - Placement of safety valves
- Section 61:08:05:22 - Safety and relief valve design
- Section 61:08:05:23 - Safety valve repair
- Section 61:08:05:24 - Safety valve capacity
- Section 61:08:05:25 - to 6:08:05:28Repealed
- Section 61:08:05:29 - Blowoff pipes and valves required
- Section 61:08:05:30 - Relief valves required with pressure reducing valves
- Section 61:08:05:31 - Pressure gauges required on low pressure side of reducing valves
- Section 61:08:05:32 - Automatic limiting devices required on steam and hot water heating boilers
- Section 61:08:05:33 - Individual control valves and drain valves required on low pressure steam boilers
Disclaimer: These regulations may not be the most recent version. South Dakota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.