South Dakota Administrative Rules
Title 44 - Department of Health
Article 44:80 - Residential hospice facilities
Chapter 44:80:10 - Construction standards
Section 44:80:10:05 - Resident rooms

Universal Citation: SD Admin Rules 44:80:10:05

Current through Register Vol. 51, page 43, September 23, 2024

A resident room shall meet the following requirements:

(1) A maximum room capacity is one resident;

(2) A minimum area, exclusive of toilet rooms, closets, lockers, wardrobes, or vestibules, of 150 square feet (13.98 square meters) in each bedroom. Any sleeping room designed as part of a suite of rooms shall have a minimum area of 120 square feet (11.15 square meters). The minimum dimension in sleeping rooms shall not be less than nine feet six inches (2.90 meters);

(3) A window sill not higher than three feet (0.91 meters) above the floor. The floor shall be above grade;

(4) A toilet room shall be attached to the resident room. The toilet room shall include a water closet, handsink, mirror, soap dispenser, towel dispenser, and private individual storage. All new construction of toilet rooms shall be wheelchair accessible;

(5) A handsink shall be provided in the room equipped with a soap dispenser and paper towel dispenser; and

(6) A separate closet space or wardrobe of five square feet (.46 meters).

General Authority: SDCL 34-12-13(3).

Law Implemented: SDCL 34-12-13(3).

Disclaimer: These regulations may not be the most recent version. South Dakota may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.