South Dakota Administrative Rules
Title 12 - Department of Agriculture
Article 12:56 - Pesticides
Chapter 12:56:13 - Bulk pesticide storage
Section 12:56:13:03 - Secondary containment
Current through Register Vol. 51, page 43, September 23, 2024
Secondary containment constructed after December 8, 1985, must be constructed according to professional engineering practices, which include the following:
(1) The walls and base must be constructed by means of either:
(2) All seams and cracks must be sealed;
(3) The capacity of the containment area must be capable of holding 110 percent of the volume of the largest container plus the volume of the butts of all the other tanks inside it; and
(4) Each cross-linked polyolefin containment structure must be permanently marked with an embossment or with a metal certification plate permanently affixed to it. The marking must be in letter and number at least 1/4 inch high located on the side of the containment structure. The marking shall certify that the containment structure complies with all requirements of this section and contain the words "meets specification of ARSD 12:56:13:03" and the date of manufacture including month and year.
General Authority: SDCL 38-20A-36, 38-21-15, 38-21-51.
Law Implemented: SDCL 38-20A-36, 38-21-15.
ASTM Standard D 1248-84, "Standard Specification for Polyethylene Plastics Molding and Extrusion Materials," American Society for Testing and Materials, January 1985. Copies may be obtained from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19193; $6.
Association of Rotational Molders Low Temperature Impact Test - T14, revised through January 1986. Copies may be obtained from Association of Rotational Molders, 435 North Michigan Avenue, Chicago, IL 60611; $4.50.