South Carolina Code of Regulations
Chapter 71 - DEPARTMENT OF LABOR, LICENSING AND REGULATION-DIVISION OF LABOR
Article 8 - OFFICE OF STATE FIRE MARSHAL
Subarticle 3 - EXPLOSIVES
Section 71-8302.5 - Records
Universal Citation: SC Code Regs 71-8302.5
Current through Register Vol. 48, No. 9, September 27, 2024
A. Licensed blasters shall keep records of each blast. The Blaster's Log shall contain the following minimum data:
1. Name of company or
contractor;
2. Location, date, and
time of blast;
3. Name, signature,
and license number of blaster in charge of blast;
4. Type of material blasted;
5. Number of holes, burden and
spacing;
6. Diameter and depth of
holes;
7. Types of explosives
used;
8. Total amount of explosives
used;
9. Maximum amount of
explosives per delay period of 8 milliseconds or greater;
10. Method of firing and type of
circuit;
11. Direction and distance
in feet to nearest dwelling house, public building, school, church, commercial
or institutional building neither owned nor leased by the person conducting the
blasting;
12. Weather
conditions;
13. Type and height or
length of stemming;
14. Whether
mats or other protections were used;
15. Type of delay electric blasting caps used
and delay periods used;
16. Exact
location of seismograph, if used, and the distance of seismograph from blast as
indicated accurately by the person taking the seismograph reading;
17. Seismograph records, where required
including:
a. Name of person and firm
analyzing the seismograph record; and
b. Seismograph reading;
18. Maximum number of holes per delay period
of eight milliseconds or greater.
B. Blasters will provide a blast report on forms approved by the OSFM and submit these forms within three working days of the blast when deemed necessary by the OSFM.
C. Blasting records shall be retained by the licensed blaster and available for inspection by OSFM during normal work hours at their place of business. These blast records shall include as a minimum for each blast:
1. Blasting Permit;
2. Seismograph reports when used;
3. Blaster's Record/log;
4. Pre-Blast Survey (if
applicable).
D. Magazine log shall be available for inspection by OSFM upon request during normal work hours or hours of operation of the magazine.
Disclaimer: These regulations may not be the most recent version. South Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.