South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-9 - Water Pollution Control Permits
Subchapter 61-9.503 - STANDARDS FOR THE USE OR DISPOSAL OF SEWAGE SLUDGE
Part E - INCINERATION
Section 61-9.503.E.43 - Pollutant limits
Current through Register Vol. 48, No. 9, September 27, 2024
(a) Firing of sewage sludge in a sewage sludge incinerator shall not violate the requirements in the National Emission Standard for Beryllium in subpart C of 40 CFR Part 61.
(b) Firing of sewage sludge in a sewage sludge incinerator shall not violate the requirements in the National Emission Standard for Mercury in subpart E of 40 CFR Part 61.
(c) Pollutant limit -lead.
C = 0.1 x NAAQS x 86,400 (Equation 4)
--------------------
DF x (1 - CE) x SF
Where:
C = Average daily concentration of lead in sewage sludge.
NAAQS = National Ambient Air Quality Standard for lead in micrograms per cubic meter.
DF = Dispersion factor in micrograms per cubic meter per gram per second.
CE = Sewage sludge incinerator control efficiency for lead in hundredths.
SF = Sewage sludge feed rate in metric tons per day (dry weight basis).
(d) Pollutant limit - arsenic, cadmium, chromium, and nickel.
C = RSC x 86,400 (Equation 5)
------------------
DF x (1 - CE) x SF
Where:
C = Average daily concentration of arsenic, cadmium, chromium, or nickel in sewage sludge.
CE = Sewage sludge incinerator control efficiency for arsenic, cadmium, chromium, or nickel in hundredths.
DF = Dispersion factor in micrograms per cubic meter per gram per second.
RSC = Risk-specific concentration for arsenic, cadmium, chromium, or nickel in micrograms per cubic meter.
SF = Sewage sludge feed rate in metric tons per day (dry weight basis).
TABLE 1 OF Section 503.43--RISK-SPECIFIC CONCENTRATION FOR ARSENIC, CADMIUM, AND NICKEL |
|
Pollutant |
Risk Specific Concentration (micrograms per cubic meter) |
Arsenic |
0.023 |
Cadmium |
0.057 |
Nickel |
2.0 |
TABLE 2 OF Section 503.43--RISK-SPECIFIC CONCENTRATION FOR CHROMIUM |
|
Type of Incinerator |
Risk Specific Concentration (micrograms per cubic meter) |
Fluidized bed with wet scrubber |
0.65 |
Fluidized bed with wet scrubber and wet electrostatic precipitator |
0.23 |
Other types with wet scrubber |
0.064 |
Other types with wet scrubber and wet electrostatic precipitator |
0.016 |
RSC = 0.0085 (Equation 6)
------
r
Where:
RSC= risk specific concentration for chromium in micrograms per cubic meter used in equation (5).
r= decimal fraction of the hexavalent chromium concentration in the total chromium concentration measured in the exit gas from the sewage sludge incinerator stack in hundredths.
(e) Air dispersion modeling and performance testing.
(f) Additional parameters may be required in the initial analysis and subsequent monitoring thereafter, but such needs will be assessed on an individual project basis. Any pollutant required for monitoring under effluent guidelines ( 40 CFR Part 136; Subchapter N ( 40 CFR Parts 400 through 402 and 404 through 471)) may be required (in a permit) to be monitored in the sewage sludge.