Current through Register Vol. 48, No. 9, September 27, 2024
(a)
Specialized definitions.
(1) "PCB
Manufacturer" means a manufacturer who produces polychlorinated
biphenyls.
(2) "Electrical
capacitor manufacturer" means a manufacturer who produces or assembles
electrical capacitors in which PCB or PCB-containing compounds are part of the
dielectric.
(3) "Electrical
transformer manufacturer" means a manufacturer who produces or assembles
electrical transformers in which PCB or PCB-containing compounds are part of
the dielectric.
(4) The ambient
water criterion for PCBs in navigable waters is 0.001 ug/l or the State
Standard as identified in S.C. Regulation Regulation
61-68 whichever is more
stringent.
(b) PCB
Manufacturer.
(1) Applicability.
(i) These standards or prohibitions apply to:
(A) All discharges of process
wastes;
(B) All discharges from the
manufacturing or incinerator areas, loading and unloading areas, storage areas,
and other areas which are subject to direct contamination by PCBs as a result
of the manufacturing process, including but not limited to:
(1) Storm water and other runoff except as
hereinafter provided in subparagraph (ii); and
(2) Water used for routine cleanup or cleanup
of spills.
(ii) These standards do not apply to storm
water runoff or other discharges from areas subject to contamination solely by
fallout from air emissions of PCBs; or to storm water runoff that exceeds that
from the ten year 24-hour rainfall event.
(2) Analytical method acceptable
-Environmental Protection Agency method specified in 40 CFR Part 136 except
that a 1-liter sample size is required to increase analytical
sensitivity.
(3) Effluent
Standards:
(i) Existing Sources. PCBS are
prohibited in any discharge from any PCB manufacturer;
(ii) New Sources. PCBs are prohibited in any
discharge from any PCB manufacturer.
(c) Electrical Capacitor Manufacturer.
(1) Applicability.
(i) These standards or prohibitions apply to:
(A) All discharges of process wastes;
and
(B) All discharges from the
manufacturing or incineration areas, loading and unloading areas, storage areas
and other areas which are subject to direct contamination by PCBs as a result
of the manufacturing process, including but not limited to:
(1) Storm water and other runoff except as
hereinafter provided in subparagraph (ii); and
(2) Water used for routine cleanup or cleanup
of spills.
(ii) These standards do not apply to storm
water runoff or other discharges from areas subject to contamination solely by
fallout from air emissions of PCBs; or to storm water runoff that exceeds that
from the ten-year 24-hour rainfall event.
(2) Analytical method acceptable.
Environmental Protection Agency method specified in 40 CFR Part 136, except
that a 1-liter sample size is required to increase analytical
sensitivity.
(3) Effluent
Standards:
(i) Existing Sources. PCBs are
prohibited in any discharge from any electrical capacitor
manufacturer;
(ii) New Sources.
PCBs are prohibited in any discharge from any electrical capacitor
manufacturer.
(d) Electrical Transformer Manufacturer.
(1) Applicability.
(i) These standards or prohibitions apply to:
(A) All discharges of process wastes;
and
(B) All discharges from the
manufacturing or incineration areas, loading and unloading areas, storage
areas, and other areas which are subject to direct contamination by PCBs as a
result of the manufacturing process, including but not limited to:
(1) Storm water and other runoff except as
hereinafter provided in subparagraph (ii); and
(2) Water used for routine cleanup or cleanup
of spills.
(ii) These standards do not apply to storm
water runoff or other discharges from areas subject to contamination solely by
fallout from air emissions of PCBs; or to storm water runoff that exceeds that
from the ten-year 24-hour rainfall event.
(2) Analytical method acceptable.
Environmental Protection Agency method specified in 40 CFR Part 136, except
that a 1-liter sample size is required to increase analytical
sensitivity.
(3) Effluent
Standards:
(i) Existing Sources. PCBs are
prohibited in any discharge from any electrical transformer
manufacturer;
(ii) New Sources.
PCBs are prohibited in any discharge from any electrical transformer
manufacturer.
(e) Adjustment of effluent standard for
presence of PCBs in intake water. Whenever a facility which is subject to these
standards has PCBs in its effluent which result from the present of PCBs in its
intake waters, the owner may apply to the Department for a credit pursuant to
the provisions of section129.6, where the source of the water supply is the
same body of water into which the discharge is made. The requirement of
subparagraph (1) of section129.6(a)(a), relating to the source of the water
supply, shall be waived, and such facility shall be eligible to apply for a
credit under section129.6, upon a showing by the owner or operator of such
facility to the Department, that the concentration of PCBs in the intake water
supply of such facility does not exceed the concentration of PCBs in the
receiving water body to which the plant discharges its effluent.