South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-79 - Hazardous Waste Management Regulations
Part 61-79.264 - STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES
Subpart F - GROUNDWATER PROTECTION RELEASES FROM SOLID WASTE MANAGEMENT UNITS
Section 61-79.264.F.99 - Compliance monitoring program
Current through Register Vol. 48, No. 9, September 27, 2024
An owner or operator required to establish a compliance monitoring program under this subpart must, at a minimum, discharge the following responsibilities:
(a) The owner or operator must monitor the groundwater to determine whether regulated units are in compliance with the groundwater protection standard under 264.92. The Department will specify the groundwater protection standard in the facility permit, including: (amended 11/90)
(b) The owner or operator must install a groundwater monitoring system at the compliance point as specified under Section264.95. The groundwater monitoring system must comply with Section264.97(a)92(a)92), (b), and (c).
(c) The Department will specify the sampling procedures and statistical methods appropriate for the constituents and the facility, consistent with 264.97 (g) and (h). (amended 11/90):
(d) The owner or operator must determine whether there is statistically significant evidence of increased contamination for any chemical parameter or hazardous constituent specified in the permit, pursuant to paragraph (a) of this section, at a frequency specified under paragraph (f) under this section.
(e) The owner or operator must determine the groundwater flow rate and direction in the uppermost aquifer at least annually.
(f) The Department will specify the frequencies for collecting samples and conducting statistical tests to determine statistically significant evidence of increased contamination in accordance with 264.97(g).
(g) Annually, the owner or operator must determine whether additional hazardous constituents from Appendix IX, which could possibly be present but are not on the detection monitoring list in the permit, are actually present in the uppermost aquifer and, if so, at what concentration, pursuant to procedures in 264.98(f). To accomplish this, the owner or operator must consult with the Department to determine on a case by-case basis: which sample collection event during the year will involve enhanced sampling; the number of monitoring wells at the compliance point to undergo enhanced sampling; the number of samples to be collected from each of these monitoring wells; and, the specific constituents from Appendix IX for which these samples must be analyzed. If the enhanced sampling event indicates that Appendix IX constituents are present in the groundwater that are not already identified in the permit as monitoring constituents, the owner or operator may resample within one month or at an alternative site-specific schedule approved by the Department, and repeat the analysis. If the second analysis confirms the presence of new constituents, the owner or operator must report the concentration of these additional constituents to the Department within seven days after the completion of the second analysis and add them to the monitoring list. If the owner or operator chooses not to resample, then he or she must report the concentrations of these additional constituents to the Department within seven days after completion of the initial analysis, and add them to the monitoring list.
(h) If the owner or operator determines pursuant to the paragraph (d) of this section that any concentration limits under Section264.94 are being exceeded at any monitoring well at the point of compliance he or she must:
(i) If the owner or operator determines, pursuant to paragraph (d) of this section, that the groundwater concentration limits under this section are being exceeded at any monitoring well at the point of compliance, he or she may demonstrate that a source other than a regulated unit caused the contamination or that the detection is an artifact caused by an error in sampling, analysis, or statistical evaluation or natural variation in the groundwater. In making a demonstration under this paragraph, the owner or operator must:
(j) If the owner or operator determines that the compliance monitoring program no longer satisfies the requirements of this section, he must, within 90 days, submit an application for a permit modification to make any appropriate changes to the program.
(k) [Removed 12/93]