(a) Each owner or operator subject to the provisions of this subpart shall comply with the test methods and procedures requirements provided in this section.
(b) Leak detection monitoring, as required in 264.1052- 264.1062, shall comply with the following requirements:
(c) When equipment is tested for compliance with no detectable emissions. as required in 264.1052(e), 264.1053(i), 264.1054, and 264.1057(f), the test shall comply with the following requirements:
(d) In accordance with the waste analysis plan required by 264.13(b), an owner or operator of a facility must determine, for each piece of equipment, whether the equipment contains or contacts a hazardous waste with organic concentration that equals or exceeds 10 percent by weight using the following:
(e) If an owner or operator determines that a piece of equipment contains or contacts a hazardous waste with organic concentrations at least 10 percent by weight, the determination can be revised only after following the procedures in paragraph (d)(1) or (d)(2) of this section.
(f) When an owner or operator and the Department do not agree on whether a piece of equipment contains or contacts a hazardous waste with organic concentrations at least 10 percent by weight, the procedures in paragraph (d)(1) or (d)(2) of this section can be used to resolve the dispute.
(g) Samples used in determining the percent organic content shall be representative of the highest total organic content hazardous waste that is expected to be contained in or contact the equipment.
(h) To determine if pumps or valves are in light liquid service, the vapor pressures of constituents may be obtained from standard reference texts or may be determined by ASTM D-2879-86 (incorporated by reference under 260.11).
(i) Performance tests to determine if a control device achieves 95 weight percent organic emission reduction shall comply with the procedures of 264.1034(c)(1) through (c)(4).