South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-79 - Hazardous Waste Management Regulations
Part 61-79.261 - IDENTIFICATION AND LISTING OF HAZARDOUS WASTE
Subpart BB - AIR EMISSION STANDARDS FOR EQUIPMENT LEAKS
Section 61-79.261.BB.1055 - Standards: Sampling connection systems
Universal Citation: SC Code Regs 61-79.261.BB.1055
Current through Register Vol. 48, No. 9, September 27, 2024
(a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed-vent system. This system shall collect the sample purge for return to the process or for routing to the appropriate treatment system. Gases displaced during filling of the sample container are not required to be collected or captured.
(b) Each closed-purge, closed-loop, or closed-vent system as required in paragraph (a) of this section shall meet one (1) of the following requirements:
(1) Return
the purged process fluid directly to the process line;
(2) Collect and recycle the purged process
fluid; or
(3) Be designed and
operated to capture and transport all the purged process fluid to a material
management unit that complies with the applicable requirements of sections
261.1084 through 264.1086 of this subpart or a control device that complies
with the requirements of section 261.1060 of this subpart.
(c) In-situ sampling systems and sampling systems without purges are exempt from the requirements of paragraphs (a) and (b) of this section.
Disclaimer: These regulations may not be the most recent version. South Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.