South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-79 - Hazardous Waste Management Regulations
Part 61-79.261 - IDENTIFICATION AND LISTING OF HAZARDOUS WASTE
Subpart BB - AIR EMISSION STANDARDS FOR EQUIPMENT LEAKS
Section 61-79.261.BB.1053 - Standards: Compressors
Current through Register Vol. 48, No. 9, September 27, 2024
(a) Each compressor shall be equipped with a seal system that includes a barrier fluid system and that prevents leakage of total organic emissions to the atmosphere, except as provided in paragraphs (h) and (i) of this section.
(b) Each compressor seal system as required in paragraph (a) of this section shall be:
(c) The barrier fluid must not be a hazardous secondary material with organic concentrations ten (10) percent or greater by weight.
(d) Each barrier fluid system as described in paragraphs (a) through (c) of this section shall be equipped with a sensor that will detect failure of the seal system, barrier fluid system, or both.
(e)
(f) If the sensor indicates failure of the seal system, the barrier fluid system, or both based on the criterion determined under paragraph (e)(2) of this section, a leak is detected.
(g)
(h) A compressor is exempt from the requirements of paragraphs (a) and (b) of this section if it is equipped with a closed-vent system capable of capturing and transporting any leakage from the seal to a control device that complies with the requirements of section 261.1060, except as provided in paragraph (i) of this section.
(i) Any compressor that is designated, as described in section 261.1064(g)(2), for no detectable emissions as indicated by an instrument reading of less than five hundred (500) ppm above background is exempt from the requirements of paragraphs (a) through (h) of this section if the compressor: