South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-64 - X-Rays (Title B)
Part II - REGISTRATION OF X-RAY MACHINES AND SERVICES
Section 61-64.II.RHB 2.2 - Exemptions
Current through Register Vol. 48, No. 9, September 27, 2024
2.2.1 Electronic equipment that produces radiation incidental to its operation for other purposes is exempt from the registration requirements of this Part, providing dose equivalent rate averaged over an area of ten square centimeters (10 cm2) does not exceed one-half millirem (0.5 mrem) per hour at five centimeters (5 cm) from any accessible surface of such equipment. The production, testing, or factory servicing of such equipment shall not be exempt.
2.2.2 Television receivers, video display terminals, and computer monitors, when used without modification to their internal or external construction, are exempt from the requirements of this Part.
2.2.3 Any facility where a federal agency has exclusive jurisdiction is exempt from the requirements of this Part.
2.2.4 X-ray machines while in transit or storage incident thereto are exempt from the requirements of this Part.