11.23.1 The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
11.23.1.1 Operability of each aspect of the access
control system required by
RHA
11.8.
11.23.1.2 Functioning of the source position
indicator required by paragraph 11.12.2.
11.23.1.3 Operability of the radiation monitor for
radioactive contamination in pool water required by paragraph 11.22.2 using a
radiation check source, if applicable.
11.23.1.4 Operability of the over-pool radiation
monitor at underwater irradiators as required by paragraph 11.11.2.
11.23.1.5 Operability of the product exit monitor
required by paragraph 11.11.1.
11.23.1.6 Operability of the emergency source
return control required by paragraph 11.12.3.
11.23.1.7 Leak-tightness of systems through which
pool water circulates (visual inspection).
11.23.1.8 Operability of the heat and smoke
detectors and extinguisher system required by
RHA
11.10 (but without turning extinguishers on).
11.23.1.9 Operability of the means of pool water
replenishment required by paragraph 11.13.3.
11.23.1.10 Operability of the indicators of high
and low pool water levels required by paragraph 11.13.4.
11.23.1.11 Operability of the intrusion alarm
required by paragraph 11.8.9, if applicable.
11.23.1.12 Functioning and wear of the system,
mechanisms, and cables used to raise and lower sources.
11.23.1.13 Condition of the barrier to prevent
products from hitting the sources or source mechanism as required by
RHA
11.14.
11.23.1.14 Amount of water added to the pool to
determine if the pool is leaking.
11.23.1.15 Electrical wiring on required safety
systems for radiation damage.
11.23.1.16 Pool water conductivity measurements
and analysis as required by paragraph 11.24.2.
11.23.2 Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.
Disclaimer: These regulations may not be the most recent version. South Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.