Section 61-63.V.RHA 5.4 - Issuance of Specific Licenses for use of Sealed Sources in Radiography

Universal Citation: SC Code Regs 61-63.V.RHA 5.4

Current through Register Vol. 48, No. 9, September 27, 2024

An application for a specific license for use of sealed sources in industrial radiography will be approved if:

5.4.1 The applicant satisfies the general requirements specified in RHA 2.6 of these regulations.

5.4.2 The applicant submits an adequate program for training radiographers and radiographers' assistants that meets the requirements of RHA 5.12.

5.4.3 The applicant submits procedures for verifying and documenting the certification status of radiographers and for ensuring that the certification of individuals acting as radiographers remains valid.

5.4.4 The applicant submits written operating and emergency procedures as described in RHA 5.13.

5.4.5 The applicant submits a description of a program for inspections of the job performance of each radiographer and radiographers' assistant at intervals not to exceed 6 months as described in RHA 5.12.5.

5.4.6 The applicant submits a description of the applicant's overall organizational structure as it applies to the radiation safety responsibilities in industrial radiography, including specified delegation of authority and responsibility.

5.4.7 The applicant identifies and lists the qualifications of the individual(s) designated as the RSO (RHA 5.22) and potential designees responsible for ensuring that the licensee's radiation safety program is implemented in accordance with approved procedures.

5.4.8 If an applicant intends to perform leak testing of sealed sources or exposure devices containing depleted uranium (DU) shielding, the applicant must describe the procedures for performing and the qualifications of the person(s) authorized to do the leak testing. If the applicant intends to analyze its own wipe samples, the application must include a description of the procedures to be followed. The description must include the following:

5.4.8.1 Instruments to be used;

5.4.8.2 Methods of performing the analysis; and

5.4.8.3 Pertinent experience of the person who will analyze the wipe samples.

5.4.9 If the applicant intends to perform "in-house" calibrations of survey instruments the applicant must describe methods to be used and the relevant experience of the person(s) who will perform the calibrations. All calibrations must be performed according to the procedures described and at the intervals prescribed in RHA 5.8.

5.4.10 The applicant identifies and describes the location(s) of all field stations and permanent radiographic installations.

5.4.11 The applicant identifies the locations where all records required by this part and other parts of this regulation will be maintained.

Disclaimer: These regulations may not be the most recent version. South Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.