South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-63 - Radioactive Materials (Title A)
Part V - SPECIAL REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS
Section 61-63.V.RHA 5.20 - Permanent Radiographic Installation
Current through Register Vol. 48, No. 9, September 27, 2024
5.20.1 Each entrance that is used for personnel access to the high radiation area in a permanent radiographic installation must have either:
5.20.2 The alarm system must be tested for proper operation with a radiation source each day before the installation is used for radiographic operations. The test must include a check of both the visible and audible signals. Entrance control devices that reduce the radiation level upon entry (designated in RHA 5.20.1.1) must be tested monthly. If an entrance control device or an alarm is operating improperly, it must be immediately labeled as defective and repaired within 7 calendar days. The facility may continue to be used during this 7-day period, provided the licensee implements the continuous surveillance requirements of RHA 5.15 and uses an alarming rate meter.
5.20.3 Each licensee shall maintain records of alarm system and entrance control device tests required under RHA 5.20.2 and retain each record for 3 years after it is made.