South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-63 - Radioactive Materials (Title A)
Part III - STANDARDS FOR PROTECTION AGAINST RADIATION
Section 61-63.III.RHA 3.3 - Units of Radiation Dose
Current through Register Vol. 48, No. 9, September 27, 2024
3.3.1 Definitions. As used in this part, the units of radiation dose are:
3.3.2 As used in this part, the quality factors for converting absorbed dose to dose equivalent are shown in Table 1.
TABLE 1: QUALITY FACTORS AND ABSORBED DOSE EQUIVALENCIES |
||
TYPE OF RADIATION |
Quality Factor (Q) |
Absorbed dose equal to a unit dose equivalent [FN2] |
X-, gamma, or beta radiation |
1 |
1 |
Alpha particles, multiple-charged particles, fission fragments and heavy particles of unknown charge...... |
20 |
0.05 |
Neutrons of unknown energy ............. |
10 |
0.1 |
High'energy protons .................... |
10 |
0.1 |
[FN2] Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 sievert. |
3.3.3 If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in rems per hour or sieverts per hour, as provided in paragraph 3.3.2 of this section, 1 rem (0.01 Sv) of neutron radiation of unknown energies may, for purposes of the regulations in this part, be assumed to result from a total fluence of 25 million neutrons per square centimeter incident upon the body. If sufficient information exists to estimate the approximate energy distribution of the neutrons, the licensee may use the fluence rate per unit dose equivalent or the appropriate Q value from Table 2 to convert a measured tissue dose in rads to dose equivalent in rems.
TABLE 2: MEAN QUALITY FACTORS, Q, AND FLUENCE PER UNIT DOSE EQUIVALENT FOR MONOENERGETIC NEUTRONS |
||
Neutron Energy (MeV) |
Quality Factor [FNa] (Q) |
Fluence per Unit Dose Equivalent [FNb] (neutrons cm-2 rem-1) |
(thermal) ........... 2.5 x 10-8 |
2 |
980 x 106 |
1 x 10-7 |
2 |
980 x 106 |
1 x 10-6 |
2 |
810 x 106 |
1 x 10-5 |
2 |
810 x 106 |
1 x 10-4 |
2 |
840 x 106 |
1 x 10-3 |
2 |
980 x 106 |
1 x 10-2 |
2.5 |
1010x 106 |
1 x 10-1 |
7.5 |
170 x 106 |
5 x 10-1 |
11 |
39 x 106 |
1 |
11 |
27 x 106 |
2.5 |
9 |
29 x 106 |
5 |
8 |
23 x 106 |
7 |
7 |
24 x 106 |
10 |
6.5 |
24 x 106 |
14 |
7.5 |
17 x 106 |
20 |
8 |
16 x 106 |
40 |
7 |
14 x 106 |
60 |
5.5 |
16 x 106 |
1 x 102 |
4 |
20 x 106 |
2 x 102 |
3.5 |
19 x 106 |
3 x 102 |
3.5 |
16 x 106 |
4 x 102 |
3.5 |
14 x 106 |
[FNa] Value of quality factor (Q) at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom. |
||
[FNb] Monoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom. |