Current through Register Vol. 48, No. 9, September 27, 2024
This standard shall apply to the construction and operation
of a barbeque pit or smokehouse room as part of a retail food
establishment.
(A)
Definition.
Barbecue is defined as a single process method
of cooking by which meat, poultry, or fish (either whole or in pieces) is
covered and slow cooked in a pit or on a spit using an indirect or direct heat
source.
(B)
General.
Barbecue pit rooms shall be located on the physical premises
of the permitted retail food establishment.
(C)
Employees.
(1) Food employees shall not contact exposed,
ready-to-eat-food with their bare hands and shall use suitable utensils such as
deli tissue, spatulas, tongs, single-use gloves, or dispensing
utensils.
(2) Personal clothing and
belongings shall be stored in a designated place away from food preparation,
food service, dry storage areas, utensil and single-service article storage,
and utensil washing areas.
(D)
Food.
(1) All food items shall be protected from
contamination during transportation, storage, cooking, display, and
service.
(2) All food employees
shall prepare, hold, and serve food according to all applicable sections of
Chapter 3 , Food.
(3) Pit rooms shall have at least one
temperature measuring device for checking temperatures of food that meets the
following requirements:
(a) Able to be
calibrated and
(b) Appropriate for
the food density being checked.
(4) Adequate refrigeration shall be provided
to support the cooking activity conducted in the pit room at the permitted
retail food establishment.
(E)
Pit-Cooking Room
Restrictions.
(1) Pit-cooking rooms
built according to these minimum construction requirements shall be restricted
to barbecue cooking equipment and the single process of cooking.
(2) No additional food preparation or
processing activities shall be permitted in the pit room unless there is full
compliance with all construction requirements pursuant to Chapter 6 of this
regulation.
(F)
Construction.
(1) All sides and
the ceiling of the pit room shall be completely enclosed.
(2) Screening may be used above wainscot
height, four (4) feet on walls, and must be at least sixteen (16) mesh per
inch.
(3) All outside openings
shall be protected against insects by tight-fitting, self-closing doors, closed
windows, screening, approved fly fans, or other means.
(4) Canvas flaps or other effective devices
may be required to protect against blowing contamination.
(5) A large tight-fitting garage door may be
allowed without a self-closer but shall remain closed during cooking
operations.
(6) Floors of
pit-cooking rooms, excluding pit floors, shall be constructed of smooth,
durable materials such as sealed concrete, quarry tile, vinyl floor covering,
or other approved material.
(7)
Floors shall be maintained in good repair.
(8) Floors approved for water flushing, such
as quarry tile or sealed concrete, shall be graded to floor drains and shall
have junctures between walls and floors sealed.
(9) Interior walls shall have smooth, easily
cleanable, and washable surfaces to at least wainscot height (4
feet).
(10) If screening is used
above wainscot, studs and other exposed bracing shall be sealed or
painted.
(11) Concrete blocks or
other masonry products used for wall construction shall be trowelled,
skim-coated, or receive sufficient coats of full strength block filler to
render a smooth surface prior to the application of a washable paint.
(12) Ceilings shall be finished to provide a
smooth, nonabsorbent, and easily cleanable surface.
(13) Trusses and rafters shall not be
exposed.
(14) Ceiling joists shall
be properly sealed.
(15)
Pit-cooking rooms shall be ventilated and kept reasonably free of excessive
heat, vapors, smoke, and fumes by ventilating the pit itself or by ventilating
the room. Pit ventilation can be achieved by a chimney or duct using dampers,
pit doors, or other devices to control airflow. Pit-cooking rooms may be
ventilated by a cathedral ceiling with screened roof-ridge vents, mechanical
exhaust fans, or other effective methods approved by the Department when pits
are not directly vented to the outside.
(16) At least twenty (20) foot-candles of
light shall be provided at all working surfaces, including the handwashing
sink.
(G)
Cooking
Pit and Cooker Construction.
(1)
Cooking pit floors may consist of a solid base of compacted clay with a top
layer of clean sand to absorb grease drippings. Sand shall be replaced as
necessary to maintain a safe and sanitary condition.
(2) Pit floors may also be constructed of
concrete, firebrick, or other material that can be cleaned and
maintained.
(3) Cooking pit walls
(exterior sides only) shall be smooth, easily cleanable, and
washable.
(4) Concrete blocks or
other masonry products used for pit construction shall be trowelled, skim
coated, or receive sufficient coats of full strength block filler applied to
the exterior wall prior to the application of a washable paint.
(5) Pit grills, grates, and other supports
shall be constructed of smooth, easily cleanable, nonabsorbent, non-toxic
material, and shall be in sections that are easily removable for
cleaning.
(6) Hog wire, chicken
wire, hardware cloth, and similar materials, that are not galvanized or have
welded joints, are permitted for single-use only and shall be discarded after
each cooking period. Expanded metal and cast iron grating are recommended
materials that can be cleaned and maintained.
(7) Pit covers shall be single-use or shall
be constructed of a smooth, easily cleanable, nonabsorbent, and non-toxic
material.
(8) The use of cookers
and mobile cookers in lieu of a barbeque pit shall require the prior approval
of the Department. These units shall be located in the pit room.
(H)
Handwashing
Sinks.
(1) Handwashing sinks shall be
provided pursuant to 5-202.12, 5-203.11, and 5-204.11.
(2) The handwashing sink shall be provided
with soap and disposable paper towels.
(3) Gloves and/or hand sanitizers shall not
be allowed as a substitute for handwashing facilities.
(I)
Authorization.
(1) No retail food establishment shall
operate a barbecue pit that does not have an authorization issued by the
Department.
(2) Any retail food
establishment that operates or proposes to operate a barbecue pit must apply to
the Department for an authorization through the application process.
(3) The following additional documentation
shall be submitted as part of the application process:
(a) Information about food prepared in the
barbecue pit room and
(b) Any other
information requested by the Department.
(4) Only a retail food establishment that
complies with the requirements of this regulation and standard shall be
entitled to receive and retain such an authorization.
(5) Once a barbecue pit has been authorized,
the Department shall be notified of any changes to the barbecue pit, such as,
but not limited to, operational changes, menu changes, or changes in the
barbecue pit in accordance with 8-304.11(B).