5-202.11 Approved System and Cleanable Fixtures.
5-202.12 Handwashing Sink, Installation.
5-202.13 Backflow Prevention, Air Gap.
An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than one (1) inch (25 mm).P
5-202.14 Backflow Prevention Device, Design Standard.
A backflow prevention device installed on the internal water supply system shall meet American Society of Sanitary Engineering (A.S.S.E.) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. P
5-202.15 Conditioning Device, Design.
A water filter, screen, and other water conditioning device installed on water lines shall be designed to facilitate disassembly for periodic servicing and cleaning. A water filter element shall be of the replaceable type.