1. All facilities shall comply with the minimum buffers listed below, as they exist at the time the permit application is received by the Department:

a. A minimum two hundred (200)-foot buffer shall be required from residences, schools, day-care centers, churches, hospitals, and publicly owned recreational park areas;

b. A minimum fifty (50)-foot buffer shall be required from property lines;

c. A minimum two hundred (200)-foot buffer shall be required from any body of water or any wetlands area; and,

d. A minimum two hundred (200)-foot buffer shall be required from public or private drinking water wells.

2. The Department may approve, with documented consent of all property owners within the buffer, less stringent buffers than those listed in this regulation.

3. The Department reserves the right to require more stringent buffers if it is determined, based on the location or operations, that more stringent buffers are necessary to protect health and the environment.

4. The Department's permit decision does not supersede, affect, or prevent the enforcement of a zoning regulation or ordinance within the jurisdiction of an incorporated municipality or county, or by an agency or department of this state.

5. Local governments may require siting criteria and buffer distances that are more stringent than the state regulations.

6. The Department may issue a variance to operate with less restrictive buffers with documented consent of all property owners within the buffer, or when the technology and practices of the operation justify the reduction. The request shall be made in writing to the Department.

7. Permitted facilities operating on the effective date of this regulation shall not be subject to the location criteria.

8. The facility shall be managed so that stormwater or floodwater is diverted around and away from the storage piles.

9. Access to the facility shall be controlled through the use of fences, gates, natural barriers, or other means approved by the Department.

10. The facility shall be bermed or given other adequate protection deemed necessary by the Department to keep liquid runoff from a potential tire fire from entering a body of water.

Disclaimer: These regulations may not be the most recent version. South Carolina may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.