South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-107 - Solid Waste Management
Subchapter 61-107.279 - SOLID WASTE MANAGEMENT: USED OIL
Subpart F - STANDARDS FOR USED OIL PROCESSORS AND RE-REFINERS
Section 61-107.279.F.53 - Rebuttable Presumption for Used Oil
Current through Register Vol. 48, No. 9, September 27, 2024
a. To ensure that used oil managed at a processing/re-refining facility is not hazardous waste under the rebuttable presumption of 279.10.b. (1)(b), the owner or operator of a used oil processing/re-refining facility must determine whether the total halogen content of used oil managed at the facility is above or below 1,000 ppm.
b. The owner or operator must make this determination by:
c. If the used oil contains greater than or equal to 1,000 ppm total halogens, it is presumed to be a hazardous waste because it has been mixed with halogenated hazardous waste listed in Subpart D of R.61-79.261. The owner or operator may rebut the presumption by demonstrating that the used oil does not contain hazardous waste (for example, by using an analytical method from SW-846, Edition III, to show that the used oil does not contain significant concentrations of halogenated hazardous constituents listed in Appendix VIII of R.61-79.261).