South Carolina Code of Regulations
Chapter 61 - DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Subchapter 61-107 - Solid Waste Management
Subchapter 61-107.19 - SOLID WASTE. MANAGEMENT: SOLID WASTE LANDFILLS AND STRUCTURAL FILL
Part IV - Class Two Landfills
Section 61-107.19.IV.C - Operation Criteria for Class Two Landfills
Current through Register Vol. 48, No. 9, September 27, 2024
1. Owners/operators of all Class Two landfills shall implement a program at the facility for detecting and preventing the disposal of regulated hazardous wastes as defined in R.61-79 Hazardous Waste Management Regulations, Part 261, polychlorinated biphenyls (PCB) wastes as defined in Resource Conservation and Recovery Act (RCRA), Part 761, and wastes not specifically allowed by the permit. This program shall include, at a minimum:
2. The Class Two landfill shall, prior to receipt of any waste materials that are not specifically listed in the permit application, submit for Department approval a characterization of the waste materials to determine the suitability for disposal in the landfill unless the Department grants an exemption for like materials.
3. Unless otherwise approved by the Department:
4. The unloading of solid waste intended for disposal in the landfill shall be restricted to the working face of the landfill. Unloading of the waste adjacent to the working face within the permitted boundaries of the landfill may be allowed for the purpose of screening the waste stream.
5. The working face of the landfill shall be confined to as small an area as the equipment can safely and efficiently operate. The slope shall not exceed 33%.
6. Solid waste shall be spread in uniform layers to the extent practical and compacted to its smallest practical volume.
7. A uniform compacted layer of clean earth cover or other suitable cover material acceptable to the Department, no less than six (6) inches in depth shall be placed over all exposed waste material at least every 30 days, unless otherwise approved by the Department. The frequency of cover may be increased or decreased as determined by the Department. More frequent cover may be required by the Department based on the nature of the disposed materials and daily disposal rate in order to address landfill gas generation, odor, leachate formation or any environmental safety and health problems.
8. Open burning at landfills is prohibited.
9. The site shall be maintained and operated in a manner that protects the established water quality standards of the surface waters and ground waters.
10. Dust, odors, fire hazards, litter and vectors shall be effectively controlled so they do not constitute nuisances or hazards.
11. The landfill shall have an attendant on duty at all times the facility is open.
12. Sign Requirements. Signs shall be posted and maintained at the main entrance that:
13. Class Two landfills shall install and maintain scales capable of accurately determining the weight of incoming waste streams. Landfills that receive less than 10,000 tons/year are exempt from this requirements.
14. On-site landfills are exempt from Sections11. 12. and 13. above.
15. Prior to accepting any materials containing asbestos for disposal at the landfill, the operator shall include in its landfill records a copy of the Permission for Disposal letter from the Department. The landfill shall retain these letters for a period of not less than three years and shall make them available to the Department upon request, if applicable.
16. Reporting Requirements.
17. Access to fire equipment and firefighting services shall be provided.
18. Procedures shall be established for maintaining conditions that are unfavorable for the habitation and production of insects, rodents and other pests.
19. A groundwater monitoring system shall be installed in accordance with Section E. below.
20. The landfill shall be adjacent to or have direct access to roads that are of all-weather construction and capable of withstanding anticipated load limits.
21. A gas monitoring system shall be designed and installed as required on a case-by-case basis to ensure that gas generated at the landfill will not create a hazard to health, safety, or property.