Roof extension insert the following:
Twelve inches (12"?) (304.8 mm)
Delete IPC section 903.2 and substitute the following:
Frost Closure: Each vent extension through a roof shall have a minimum size of three inches (3"?) in Providence County and two inches (2"?) in all others. Where this results in an increase in size of the vent extension, the change in diameter shall be made inside the building a minimum of six inches (6") below the roof with an approved fitting.
Disclaimer: These regulations may not be the most recent version. Rhode Island may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.