G2406.2 (303.3) Add the following new exception:
G2415.3 Delete G2415.3 and substitute the following:
G2415.3 (401.1) Prohibited locations.
Piping shall not be installed in or through a ducted supply, return or exhaust, or a clothes chute, chimney or gas vent, dumbwaiter or elevator shaft. Piping installed downstream of the point of entry may extend through any townhouse unit other than the unit served by such piping.
G2415.6 Delete and substitute the following:
G2415.6 (404.4) Piping through foundation wall.
Underground piping, where installed below grade through the outer foundation or basement wall of a building, shall be encased in a protective pipe sleeve.
The annular space between the gas piping and the sleeve shall be sealed.
G2425.15 Add the following exception to G2425.15.1:
Exception:
Installation of replacement appliances below an eighty-five percent (85%) AFUE rating shall be exempt from the requirement of installing a new chimney liner and must meet the manufacturer's recommendations for installation in an unlined chimney.