R905.2.6 Delete section R905.2.6 and substitute the following:
R905.2.6 Attachment.
Asphalt strip shingles shall have a minimum of six (6) fasteners per shingle.
Exceptions:
1.
Where the roof slope exceeds twenty (20) units vertical in twelve (12) units
horizontal (20:12), special fastening details may be required by the
manufacturer.
2. Fastening systems
tested by the manufacturer to ASTM D3161 modified to use a wind speed of one
hundred ten (110) MPH shall be permitted to be installed in any wind
zone.
R905.2.8.2 #3 Delete and
substitute the following:
R905.2.8.2 #3
3. For closed valleys (valley covered with
shingles), valley lining of one ply of smooth roll roofing complying with ASTM
D224 Type II or Type III and at least thirty-six inches (36") (914 mm) wide or
valley lining as described in Items 1 and 2 above shall be permitted. Specialty
underlayment complying with ASTM D 1970 may be used in lieu of the lining
material. Other valley lining systems and techniques acceptable to the shingle
manufacturer shall be approved by the Building Official.
Disclaimer: These regulations may not be the most recent version. Rhode Island may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.