Rhode Island Code of Regulations
Title 510 - Building Code Commission
Chapter 00 - N/A
Subchapter 00 - N/A
Part 1 - RISBC-1 Rhode Island Building Code
Section 510-RICR-00-00-1.12 - Chapter 14: Exterior Walls
Current through September 18, 2024
Add the following new subsection to IBC section 1404.1 General:
1404.1.1 Re-siding Exterior Walls.
Materials and methods of application used for re-siding or replacing an existing wall covering shall comply with the requirements of this section. New Exterior side wall covering shall not be installed without first removing existing wall coverings when any of the following conditions occur:
Exception: The total number of wall coverings shall not be limited when any of the existing wall coverings consists of asbestos cement board or asbestos cement shingles or any protective encapsulating or protective siding/layer immediately over the asbestos material.
Delete IBC section 1406.3 exceptions 3 and 4 and substitute as follows:
Balconies and similar projections of combustible construction, other than fire-retardant-treated wood, shall afford the fire-resistance rating required by Table 601 for floor construction or shall be of Type IV construction as described in section 602.4, and the aggregate length shall not exceed fifty percent (50%) of the building perimeter on each floor.
Exceptions: