Winding drums and sheaves shall be composed of cast iron or steel. The diameter of drums or sheaves shall be not less than 30 times the diameter of the wire hoist-ropes and shall have machined rope-grooves. An exception exists when eight by 19 elevator wire rope or seven by 19 aircraft cable is used as a connecting means between the carriage and the driving machine, the diameter of drums and sheaves may be reduced to 21 times the diameter of the rope or cable.

Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.