Pennsylvania Code
Title 34 - LABOR AND INDUSTRY
Part I - Department of Labor and Industry
Chapter 7 - ELEVATORS, LIFTS, ESCALATORS, DUMBWAITERS, HOISTS ANDTRAMWAYS
Subchapter H - STAIRWAY INCLINED LIFTS IN BUILDINGS OTHER THAN PRIVATE RESIDENCES
Section 7.256 - Operating device
Universal Citation: 34 PA Code ยง 7.256
Current through Register Vol. 54, No. 38, September 21, 2024
Operating shall be by continuous-pressure, key-operated switches, at the terminal landings only. Switches shall be so arranged that they do not remain in the "run" position unless forcibly held in such position, and automatically return to the "off" position and the key ejected from the switch if released. Keys shall be placed only in the hands of designated responsible persons and not be indiscriminately distributed, so that operation of the device may be closely supervised by a competent person at a terminal landing only. Key switches shall be so located as to permit an unobstructed view of the entire length of travel of the lift.
Disclaimer: These regulations may not be the most recent version. Pennsylvania may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.